Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Nanoscale Res Lett ; 9(1): 465, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25246870

RESUMO

In this paper, we report the facile preparation of monodisperse titanium dioxide-diltiazem/tetrachlorobismuth core-shell nanospheres (TiO2@DTMBi), in which, diltiazem (DTM)/tetrachlorobismuth (BiCl4) complexes were employed as electroactive materials. The morphology, size, formation, and structure of the obtained TiO2@DTMBi spheres were investigated by transmission electron microscopy, scanning electron microscopy, dynamic light scattering, Fourier transform infrared spectroscopy, and X-ray diffraction. The optimal condition of obtained monodisperse 40-nm TiO2@DTMBi spheres was researched. The results of using TiO2@DTMBi nanospheres as proposed drug sensor indicate a wide linear range (10(-7) to 10(-1) M) and a very low detection limit of 0.20 µg/mL.

2.
Electron. j. biotechnol ; 17(4): 183-188, July 2014. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-719110

RESUMO

Background A simple, rapid, low-cost and environmentally friendly method was developed to determine dopamine (DA) in the presence of ascorbic (AA) and uric acid (UA) based on a novel technique to prepare a graphene-chitosan (GR-CS) nanocomposite and modify it on the surface of carbon paste electrode (CPE). For our design, CS acts as a media to disperse and stabilize GR, and then GR plays a key role to selective and sensitive determination of DA. Results Under physiological conditions, the linear range for dopamine was determined from 1 × 10- 4 to 2 × 10- 7 mol/L with a good correlation coefficient of 0.9961 in the presence of 1000-fold interference of AA and UA. The detection limit was estimated to be 9.82 × 10- 8 mol/L (S/N = 3). In order to study the stability and reproducibility, GR/CS/CPE underwent successive measurements in 10 times and then tested once a d for 30 d. The result exhibited 98.25% and 91.62% activities compared with the original peak current after 10-time measurements and 30-d storage. Conclusion The GR/CS/CPE has wide linear concentration range, low detection limit, and good reproducibility and stability, which suggests that our investigations provide a promising alternative for clinic DA determination.


Assuntos
Carbono/química , Dopamina/análise , Quitosana/química , Grafite/química , Eletrodos , Nanocompostos/química , Técnicas Eletroquímicas , Limite de Detecção , Técnicas de Química Sintética , Concentração de Íons de Hidrogênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...